Orpheum Theatre

Technical Specs

This page provides detailed information on the Orpheum Theatre's technical capabilities, and equipment to assist in planning and executing successful performances. It covers stage dimensions, lighting and sound systems, rigging, and other technical resources. Please review the following specifications to facilitate your planning process.

Orpheum Theatre

Expand each section below for full information. Click here to download the full technical specs.

Street Address:

Orpheum Theatre, 203 S. Main St. Memphis, TN 38103


Stage Door:

On Beale St. between Front St. and Main St.


Mailing Address:

Orpheum Theatre, P.O. Box 3370, Memphis, TN 38173

President & CEOBrett Batterson: 901-529-4224
Executive Vice President & CFO Paulette Luker: 901-529-4225
Vice President & COODacquiri Baptiste: 901-529-4248
Director of Facilities and Engineering Richard Reinach: 901-529-4232
Technical DirectorCharles “Chuck” Materna: 901-529-4286
Administration901-525-7800
Box Office 901-525-3000
Backstage Security901-529-4235
Stagehands

I.A.T.S.E. Local #69: 901-327-4994

Business Agent: Andrea Hoffman

President: Allen Byassee

Wardrobe and Hair

I.A.T.S.E. Local #825: 901-218-3449

Business Agent: Stacy Caldwell

President: Margaret Morgan

Main Stage
(lighting, color, lamps, tape)
901-274-4444
Tennessee Concert Sound
(audio)
731-772-2292
Nolan’s
(audio, visual, lighting)
901-527-4313
Keyboards in Black and White
(backline)
901-550-5780
ProShow Systems
(Audio and Lighting
901-327-0550
Pro Audio
(audio)
901-323-1066
Profound Sound
(audio)
901-849-2983
Yarbrough Music
(instruments)
901-761-0414

FROM THE NORTH: Take I-55 South to I-40 East. Cross the Mississippi on the Arkansas-Tennessee Bridge. Take exit #1, the Front St. South exit, just before you get off the bridge. Turn right and follow Front St. to Beale St. Cross Beale St. The loading dock is on your left on the corner of Front St. and Beale St.

FROM THE WEST: Take I-40 East. Cross the Mississippi on the Arkansas-Tennessee Bridge. Take exit #1, the Front St. South exit, just before you get off the bridge. Turn right and follow Front St. to Beale St. Cross Beale St. The loading dock is on your left on the corner of Front St. and Beale St.

FROM THE SOUTH: Take I-55 North. Take exit 12-A, Crump St. East. Follow Crump St. East to 3rd St. Turn left. Follow 3rd St. to Linden St. Turn left. Follow Linden St. 3 stoplights to Front St. Turn Right. The loading dock is on your right on the corner of Front St. and Beale St.

FROM THE EAST: Take I-40 West. Take exit 1-C, (Hwy 51 South) Danny Thomas Blvd. south. Follow Danny Thomas Blvd. south to Linden St., turn right. Follow Linden St. west to Front St., turn right. The loading dock is on your right on the corner of Front St. and Beale St.

FROM EAST MEMPHIS: Take I-240 towards Jackson, MS. At the I-240 / I-55 connector, take I-55 towards St, Louis. I-55 North brings you to downtown Memphis. Exit I-55 at Riverside Drive, follow Riverside Drive north. Turn right at the first stoplight. This will be Beale Street. The theatre is located two blocks east on Beale at the corner of Beale and South Main.

FROM THE WEST ON I-55: Cross the Arkansas – Tennessee Bridge. Take the second exit after crossing the bridge. This will be the Riverside Drive exit. Travel Riverside Drive north. Turn right at the first stoplight. This will be Beale Street. The theatre is located two blocks east on Beale at the corner of Beale and South Main.

FROM THE WEST ON I-40: Cross the new Arkansas – Tennessee Bridge. Take the first exit. This will be the Riverside Drive exit. Follow Riverside Drive south, until you reach Beale Street. Turn left onto Beale Street. The theatre is located two blocks east on Beale at the corner of Beale and South Main.

FROM THE AIRPORT: Leaving the Airport, turn west onto Winchester. Follow Winchester to the I-55 interchange. Enter I-55 north. I-55 north brings you to downtown Memphis. Exit I-55 at Riverside Drive, follow Riverside Drive north. Turn right at the first stoplight. This will be Beale Street. The theatre is located two blocks east on Beale at the corner of Beale and South Main.

ONCE YOU HAVE ARRIVED: There is no free parking. Parking is available at several public lots surrounding the theatre. Parking may be a problem. There are many facilities that utilize the public lots. We recommend that you arrive at least 30 - 45 minutes before curtain to take advantage of parking in this immediate area.

Additional direction and parking information is available here.

Proscenium Opening30’ – 0” x 54’- 0”
Grid

Grid Height: 65’ – 3”

Pipe Travel: 59’ - 0” (House Electrics 58’ – 2”)

NOTE: Grid limit – 60 #PSF

Stage Depth

Stage lip: 4’ – 4” at center, 2’8” at SR & SL edges
(from plaster line)

Downstage edge /orchestra pit: 14’ – 7”

Last line set: 49’ – 10"

Upstage Columns: 50’ – 0”

Back wall: 51' – 4”

NOTE: sprung floor rated to 375 # PSI, 300# PSF

Stage Width

Wall to wall: 106’ – 1”

Ctr to SL wall: 55’ – 7”

Ctr to SL column: 47’ – 11”

Ctr to SR lock rail: 50’ – 6”

Ctr to SR column: 47’ – 11”

Plaster Line at Center Stage To

Balcony rail: 65’ – 0”

Box Booms: 60’ – 0”

Cove: 125’ – 0”

Spot Booth: 120’ – 0”

Mix Position (sound and light board) 88’ – 0”

1st row of seats: 18’ – 0”

Curtain Line To

Stage lip: 7’ – 0”

Downstage edge of orchestra pit: 17’ – 3”

Loading Dock

3 Doors @ 11’ – 4” x 9’ – 4”

Located at rear of theatre on Front St.

Beale Street Door8’ X 8’ Door, 1’-6” down from street to stage level
Freight Elevator

Loading dock to Wardrobe room-2nd floor

Door size: 7’ – 0”h x 8’ – 0” w

Compartment size: 7’ – 9” w x 9’ – 4” d

Orchestra Pit

Moving section: 10’ – 2” d @ center x 35’ – 6” w

Fixed section: 11’ – 0” d x 32’ – 1” w

Organ pit: 11’ – 4” w x 9’ – 4” d

90-single purchase line sets

6-hoist lines each

Wells are 14’ apart and split center (Also well at center)

1 1/2” pipe @73’ – 0” long

7’ – 0” arbors rated @ 1100#

Locking rail at stage level SR and +32’- 0” SR

Pin rails located SL & SR. elev. +32’ – 0”

SL 40 pins

SR 40 pins (2nd lock rail)

Rope: 5000’ of 5/8” hemp

Spot line sheaves – 40

NOTE: Sheaves on line set #44 can move DS only. Sheaves on line set #53 ,#54 & #55 cannot be moved. Sheaves on line set #62 can move DS only. Sheaves on line set #63 can move US only.

Line set #61 useable but very tight. #62, #63, #64, and #65 are pulled behind a column and very tight.Shape

1 valance @ 16’ x 60’ – Rust color

1 main curtain, 2@ 31’ x 32’ (travel or guillotine from SR) 2 people to operate

5 sets black legs (flat) @ 31’ – 0” x 16’ – 0”

2 black borders @ 12’ x 60’

6 black borders @ 8’ – 0” x 60’ – 0”

2 full black out drops @ 31’ – 0” x 60’ – 0”

1 black sharkestooth scrim @ 31’ – 0” x 64’ – 0”

1 white sharkestooth scrim @ 29’ – 0” x 64’ – 0”

1 white “leno” filled scrim cyc @ 29’ – 0” x 64’ – 0”

Fiber Optic Star Drop 30’ X 60’ (6 light emitters)

1 Harkness Matt Plus movie screen 54’ x 30’

Lighting Desk

ETC Element 60

  • 500 Channels
  • 2 DMX ports
  • 60 sub masters
Dimming and Circuits

192 @ 2.4kw ETC Sensor +

9 @ 6kw ETC Sensor +

48 @ 2.4kw ETC sensor rack (SL & SR)

(ETC Dimmers are driven by DMX-B)

285 dimmers available

Instrumentation Over Stage

6 @ ETC Source Four 50° (575-X)

48 @ ETC Source Four 36° (575-X)

33 @ ETC Source Four 26° (575-X)

38 @ ETC Source Four 19° (575-X)

9 @ ETC Source Four 10° (575-X)

95 @ ETC Source Four PAR (575-X)

12 @ 8” Fresnel (2kw)

12 @ 2 cell cyc lights (1kw)

10 @ chroma Qs spec for high CYC use only

Front of House

(standard house hang)

Cove: 24 @ 5° ETC Source Four / 24 @ 2.4kw circuits 125’ to stage

Box Booms (per side): 10 @ 19° ETC Source Four / 12 @ 2.4kw circuits 60’ to stage

Balcony Rail: 30 @ 2.4kw circuits

Follow Spots4 @ 3kw Xenon Lycian 1293’s
Road Power

Front of house patch (transfer) located DSR

87 FOH circuits

DSR 3 @ 400A / 120 / 208 volt / 3 phase

USR 2 @ 400A / 120 / 208 volt / 3 phase

USL 1 @ 400A / 120 / 208 volt / 3 phase

MSL 1 @ 200A / 120 / 208 volt / 3 phase isolated ground

Miscellaneous

side arms, roto-locks, cheeseboros

8 @ 50# boom bases, pipe: 10’, 15’, & 21’ lengths

Shape

Sound Desk

Yamaha QL5-32 Digital Mixing Console

Yamaha LS9-32 digital mixing console

Speakers

Meyer Line Array system
Meyer Line array – Mina Cab. Flown 16 SR & 16 SL
Center cluster: 16 Mina Cabinets
On Stage: 4 @ Meyer 1100 LFC Bass Cabinets
In House: Front Fills – 4 @ Meyer M1D

Delay fills
8 @ Meyer UP Junior-XP Orchestra Level
8 @ Meyer UP Junior XP Mezz Level
2 @ Meyer UP4 XP Upper Gallery Level

Wedges
4 @ Turbosound TFX 122M-AN Powered monitor wedges
4 @ Wharfdale EVP X15M monitor wedges

System Power

Self powered Meyer speakers.

Crown com-tech (70-volt, Backstage Program)

Microphones

7@ Shure SM 58

6 @ Shure SM 57

6 @ Shure Beta 56A

2 @ Shure Beta 52

2 @ AKG SR 450 Wireless (handheld & belt pack)

3 @ AKG 452

3 @ Crown PCC 160

4 @ EV RE16-4

7 @ Whirlwind passive DI

2 @ EV Polar Choice Podium Mics

PlaybackCD player available
Intercom

Clear-com CS 200

14 @ Headsets & belt packs

3 @ biscuits with handsets

Sound Reinforcement Consists of

Left / Right Array & Center Array

Front Fills

Under balcony fills

Mix Position

Located house left of center aisle on orchestra level

Size: 19’ – 7” x 9’ – 0” (shared with light board)

88’ – 0” from down stage center

On Stage Monitor SystemNone available
Program and PageIn all support areas

From stage floor to plaster line

Height3'15' 24'48'
Distance Front Flat0'76'57'94'
Distance Front With Angle0'78'62'105'
Distance Flat Back94'94'94'108'
Distance Back With Angle94'95'101'122'
Angle12° 22°27°

Eiki LC-S6, 5.8K digital projector

Barco RLM-W8 (8000 Lumens)

Both projectors share switcher rack.

Switcher rack w/ 3 Blu-Ray players, VHS, and serial inputs

2 @ 35mm film projectors

Front Projection Screen – 10.5’ x 14’

Harkness Matt Plus Cinemiracle Screen – 54’ x 30’

Stage Level1 Star Dressing Room
Above Stage

2 @ 2 person (star) stations

2 @ 8 person stations

4 @ 17 person stations (chorus rooms)

Below Stage

3 @ 6 person stations

1 @ Production office / Orchestra room

Note12 total. All dressing rooms have rest rooms with showers, make-up counters, Broadway style make-up lights, individual climate control, program and paging. Most dressing rooms have phone lines and high speed internet hook-ups available.

Need complete specs?